Kinetec
Maestra Hand and Wrist CPM Machine Specifications:

Range of Motion: |
Fingers:
45° hyperextension, 270° flexion (full fist) |
| Weight:
|
23
lbs. (10.5kg) |
| Thumb: |
Full
opposition |
| Wrist:
|
55°
flexion – 90° extension
90° pronation– 90° supination
Full abduction/adduction |
| Intrinsic
+ : |
0°
extension– 90° flexion |
| Intrinsic
- : |
0°
extension– 180° flexion |
| DIP: |
0°
– 70° |
| Approval:
|
UL-Listed |
| Warranty: |
24-month
limited |
|
|
|
|
Indications:
• Flexor and extensor tenolysis
• Aponeurectomies for Dupuytrens disease
• Metacarpophangeal arthrolysis
• Open reduction and internal fixation of intra-articular, diaphyseal,
metaphyseal and epiphyseal fractures of the phalanges
• Prosthetic replacement of the MCP, PIP and DIP joints
• Rheumatoidal/neurological or after-burn stiffness
• Capsulotomies, arthrolysis and tenolysis for post-traumatic
stiffness of MCP, PIP and DIP joints
• Synovectomies |
|
Maestra
Hand and Wrist CPM
Help your patients
prevent post-operative joint stiffness with the Kinetec Maestra Hand and
Wrist CPM Machine. Its patented drive mechanism allows continuous motion
that matches the natural physiological spiral of flexion. This lightweight,
easily-transportable unit also features variable speed control, variable
range of motion, and a pivoting palm support for increased comfort, while
its easy-to-use cursors protect healing tissue by limiting range of motion.
Numerous attachments allow a wide variety of applications.
|
Order
Here !!
|
|
Code
|
Description
|
|
929394
HCPCS
Code: E0935
|
Maestra
Hand and Wrist CPM $5,495.00
|
| 53151909 |
Replacement
Patient Pad Kit $45.95
|
|
|
|
Maestra
Hand & Wrist CPM

|
|
| |
|
Help
your patients prevent post-operative joint stiffness with the
Kinetec Maestra Hand and Wrist CPM Machine. Its patented drive
mechanism allows continuous motion that matches the natural physiological
spiral of flexion. This lightweight, easily transportable unit
also features variable speed control and a pivoting palm support
for increased comfort, while its easy-to-use cursors protect healing
tissue by limiting range of motion.
|
| Features |
Benefits |
|
|
|
- On/off/reverse
patient switch
|
|
|
|
- Allow
a choice of applications
|
|
|
|
|
|
- Adaptable
to specific therapy requirements
|
- Natural
spiral of flexion for
|
- More
natural movement; true composite fist fingers and thumb
|
|
|
- Patient
trust and compliance are increased
|
- One
machine for fingers,
thumb and wrist
|
|
- 24-month
limited warranty
|
|
|
|
|
- Flexor
and extensor tenolysis
- Aponeurectomies
for Dupuytrens disease
- Metacarpophangeal
arthrolysis
- Open
reduction and internal fixation of intra-articular, diaphyseal,
metaphyseal and epiphyseal fractures of the phalanges
- Prosthetic
replacement of the MCP, PIP and DIP joints
- Rheumatoidal/neurological
or after-burn stiffness
- Capsulotomies,
arthrolysis and tenolysis for post-traumatic stiffness
of MCP, PIP and DIP joints
- Synovectomies
|
|
| Technical
Specifications |
Range
of Motion: Fingers: 45° hyperextension, 270° flexion (full
fist)
Thumb: Full opposition
Wrist: 55° flexion - 90° extension
90° pronation - 90° supination
Full abduction/adduction
Intrinsic + : 0°extension, 90° flexion
Intrinsic - : 0°extension, 180° flexion
DIP: 0°-70°
Weight: 23 lb. (10.5kg) |
|